Selection of the CBMPD188B photodetector module: Specifications are only half the story—do not overlook the test conditions.
  • Released:2026-11-25 13:59:54
  • Views 9 次
CBMPD188B 是芯佰微的高度集成光电探测模组,单芯片整合光电测量模拟前端、ADC、LED 驱动器、时序控制器与 1024 字节 FIFO,适用于消防烟雾报警器、空气颗粒物检测、环境光测量、气体检测与其它胶体浓度检测这类微弱光信号探测场景的评估。 【核心亮点抢先看】 ▶ 129dB 动态范围(接收链路、单次采样),多重转换模式下 ADC 输出分辨率最高可配置至 24 bit ▶ 4 路差分/单端或 8 路单端光电二极管输入,4 个独立配置时隙,采样速率 0.002Hz~16kHz

The CBMPD188B is a highly integrated photodetector module from Corebai. The single chip integrates the photometric measurement analog front-end, ADC, LED driver, timing controller, and a 1024-byte FIFO. It is suitable for evaluation in applications involving the detection of weak light signals, such as fire smoke alarms, airborne particulate matter detection, ambient light measurement, gas detection, and other colloidal concentration detection scenarios.

[Key Highlights Preview]

▶ 129 dB dynamic range (receive chain, single sampling); in multiple conversion modes, the ADC output resolution can be configured up to 24 bits.

▶ 4-channel differential/single-ended or 8-channel single-ended photodiode inputs; 4 independently configurable time slots; sampling rate: 0.002 Hz to 16 kHz

▶ 60 dB high ambient light suppression (DC–1 kHz); 3 programmable constant-current LED drivers, with a maximum current of 240 mA per channel

▶ Typical total system power consumption is 20 µW (single time slot, single channel, 25 Hz, including a 25 mA @ 3 V / 3 µs LED pulse, at 25 °C); standby current is 1.5 µA; OLGA-24 package.

image.png 

Detection link and dynamic range

Q1: What does a dynamic range of 129 dB mean, and can it be directly compared with a signal-to-noise ratio of 80 dB?

A: The value of 129 dB represents the dynamic range metric under receiver-link conditions and for a single sample acquisition. The product specifications do not provide the calculation formula or the complete test configuration; therefore, when citing this value, one should follow the given conditions and should not derive it independently. The signal-to-noise ratio is a different type of metric: under conditions of a 90% full-scale signal, a 4 µs integration window, and inclusion of photodiode noise, the SNR decreases from 80 dB at a TIA feedback resistor of 12.5 kΩ to 67 dB at 1.6 MΩ. The test conditions for these two metrics differ; thus, the dynamic range metric cannot be recharacterized as the signal-to-noise ratio, and the value of 80 dB cannot be used as a substitute. When evaluating the capability to detect weak signals, one may consider both the dynamic range and the equivalent input noise. To assess the signal-to-noise performance near full scale, refer to the set of values obtained under the 90% full-scale condition.

Q2: How should the TIA feedback resistor be selected, and how do the input current resolution, noise, and signal-to-noise ratio change accordingly?

A: The input current resolution is specified for a single-pulse duration of 3 µs and an integration window of 4 µs; the equivalent input noise is determined with the LED off and the integration window set at 4 µs; the signal-to-noise ratio is specified at 90% of full scale, with an integration window of 4 µs and including photodiode noise. All three sets of data correspond to the respective ranges of TIA feedback resistors:

TIAfeedback resistance

Input current resolution (nA/LSB)

Equivalent input noise (nA RMS)

noise-signal ratio(dB)

12.5KΩ

1.6

4.5

80

25KΩ

0.8

2.4

78

50KΩ

0.4

1.1

76

100KΩ

0.2

0.58

75

200KΩ

0.1

0.33

74

400KΩ

0.05

0.19

73

800KΩ

0.025

0.10

70

1.6MΩ

0.012

0.06

67

The feedback resistance increased from 12.5 kΩ to 1.6 MΩ; the input current resolution improved from 1.6 nA/LSB to 0.012 nA/LSB; and the equivalent input noise decreased from 4.5 nA RMS to 0.06 nA RMS. In exchange, the TIA saturation current decreased from 100 µA to 0.78 µA. As an initial guideline, in environments with strong background light, a lower resistance value may be preferred to preserve the measurement range; in applications involving weak signals, a higher resistance value may be preferred to enhance sensitivity. The specific value to be selected should still be determined by considering the photocurrent range, whether saturation occurs, and the combined effects of noise and photodiode capacitance.

Q3: What problems do the multi-pulse integration mode and the multi-conversion mode address, respectively? How is the 24-bit output resolution achieved?

A: The multi-pulse integration mode is designed for applications involving weak signals. The multi-conversion mode can be configured to improve the resolution of the conversion results; the actual performance must be validated based on the specific application. The ADC resolution is typically 16 bits and up to 24 bits; the actual value depends on the NUM_REPEAT_TSX configuration. In single-slot operation, the sampling rate can be configured within the range of 0.002 Hz to 16,000 Hz; slow-speed measurements can be achieved by employing longer integration and conversion processes. The chip also incorporates an integrated timing controller, which, together with the LED driver and FIFO, completes the entire acquisition process. The 24-bit figure refers to the maximum configurable output resolution of the ADC; it does not represent the default output bit width, nor is it equivalent to measurement accuracy. The actual effective number of bits and measurement accuracy depend on the configuration, noise levels, and system design. Therefore, before making any estimates, ensure that NUM_REPEAT_TSX has been set to the appropriate level.

Multi-channel and optical configurations

Q4: How should I understand the configuration involving 4-channel differential/single-ended or 8-channel single-ended inputs, and how are the time slots allocated?

A: The product specifications on the home page list two input configuration options: 4-channel differential/single-ended input, or 8-channel single-ended input. The pin layer provides two opto-current input channels, EXT_IN1 and EXT_IN2, as well as a PDC bias voltage output. The four time slots can be configured independently for synchronized measurement of multiple parameters. The specified sampling rate range of 0.002 Hz to 16 kHz is explicitly applicable to single-time-slot operation; the usable sampling rate for multi-time-slot systems must be evaluated based on the actual configuration. Whether the time slots are fully utilized depends on the LEDs, the opto-current channels, the sampling timing, and the host's read requirements; configuration should be based on the number of measurement parameters.

Q5: How can the sensitivity of the on-chip photodiode and the light transmittance of the package be utilized in optical design?

A: The performance specifications indicate an on-chip photodiode sensitivity of 0.6 A/W (at 940 nm); for the OLGA package, the transmittance across the 450–950 nm wavelength range is at least 99%. This 99% refers to the transmittance of the package itself; additional losses may result from the housing, window, filter, and incident angle. If the detection wavelength falls outside the 450–950 nm range, the assumption of 99% transmittance no longer holds, and the optical link must be recalculated based on the actual wavelength.

Q6: What field issues can be addressed by 60 dB environmental light suppression (DC–1 kHz)?

A: The environmental-light suppression ratio is 60 dB and covers the frequency range from DC to 1 kHz, corresponding to constant background light and low-frequency fluctuations in illumination. In applications such as fire-smoke detection and air particulate detection, where it is necessary to distinguish weak scattered light against natural and artificial lighting backgrounds, this metric helps mitigate the influence of environmental light within the specified frequency band. The actual suppression performance depends on the optical path, modulation method, configuration, and on-site conditions. The 60 dB specification refers to the background light in the DC–1 kHz range; rapid changes in illumination outside this band are not covered by the specification. Optical-path shading and the modulation method of the light source still need to be evaluated in light of the actual on-site lighting conditions.

Power Consumption and Power Supply Design

Q7: Under what conditions is the total system power consumption of 20 µW specified?

A: The typical value of the total system power consumption, ITPW, is 20 µW, corresponding to a specific set of operating conditions: one time slot, one channel, a data output rate of 25 Hz, TC = 25 °C, and including the LED current—namely, an LED pulse current of 25 mA, an LED voltage of 3 V, and a pulse width of 3 µs. This refers to the pulse current, not the continuous current; the value of 20 µW represents the typical total system power consumption under the aforementioned complete set of specified conditions. Under the same operating conditions, the typical operating current IVDD is 8.3 µA (excluding the LED current), and the typical total system current ITC is 10 µA (including the LED current). The value of 20 µW is the typical value for this particular set of operating conditions, not the power consumption across all possible operating conditions; recalculations are required whenever the number of time slots, the number of channels, the sampling rate, or the LED pulse parameters are changed. When estimating battery life using the 20 µW figure in battery-powered designs, the target sampling rate, the LED duty cycle, and the power supply rail voltage must be taken into account and the calculation recalculated; otherwise, the average power consumption may be underestimated.

Q8: How should the standby, peak, and power-supply ranges be determined? What are the boundaries of the absolute maximum ratings?

A: Standby current: 1.5 µA; peak current: 5.9 mA; both values are specified at 25 °C. The recommended operating supply voltages are VDD1/VDD2: 1.7–1.9 V (typical: 1.8 V) and IOVDD: 1.7–3.6 V (typical: 1.8 V or 3.3 V). The absolute maximum ratings include: VDD1/VDD2: −0.3–1.9 V; IOVDD: −0.3–3.6 V; VLEDB: −0.3–5.5 V; VLEDI: −0.3–4.2 V; storage temperature: −45–125 °C. The ESD tolerance is HBM 4000 V and CDM 500 V. The supply voltage margin is based on the recommended operating range; the absolute maximum ratings serve only as transient safety boundaries and should not be used as normal operating points.

Q9: How are the current capability and voltage drop of a 3-channel LED driver calculated?

A: The 3-channel LED driver supports programmable constant-current driving, with pulsed current per channel ranging from 1 to 240 mA. The driver's voltage drop increases with current when IOVDD = 3.3 V: it is 65 mV at 25 mA, 80 mV at 100 mA, and 220 mV at 230 mA. The maximum off-state leakage current is 57 nA, and the maximum port voltage is 3.6 V—the port voltage is not equivalent to the LED anode voltage. Under high-current pulses, the voltage drop rises to 220 mV. When calculating the voltage drop in the LED circuit and the power-supply margin, the corresponding value based on the actual pulsed current should be used; it is not advisable to estimate it uniformly as 65 mV. If the upper limits for all three channels need to be reached simultaneously, the total current, power supply requirements, and thermal design must also be considered together in the verification process.

Data Interfaces and Configuration Selection

Q10: How should the I2C interface speed, bus load, and pull-up resistor be determined?

A: The chip provides a standard I2C communication interface, with a maximum clock frequency FSCL of 1000 Kbps, a maximum bus load Cload of 30 pF, and an external pull-up resistor REPU that must be at least 800 Ω. On the pins, SCL serves as the clock input, and SDA serves for data transmission and reception; the digital input voltage range is bounded above by IOVDD, and the I2C logic levels must match those on the master-control side. The values of 30 pF and 800 Ω represent boundary conditions specified in the given parameters; they do not constitute universally guaranteed values for arbitrary combinations. The pull-up resistance must be calculated taking into account the bus capacitance and the signal rise time. In cases involving long traces or multiple devices connected to the bus, the waveform should be measured experimentally before the resistance value is finalized.

Q11: How should the 1024-byte FIFO be coordinated with the sampling rate?

A: The on-chip 1024-byte FIFO is used to cache the conversion results. Under single-slot operation, the sampling rate can be configured within the range of 0.002 Hz to 16,000 Hz. During low-speed continuous monitoring, the FIFO can accumulate a relatively large number of samples, which can then be read centrally by the host, thereby reducing the frequency of bus accesses. When the rate is increased, the corresponding caching duration is significantly shortened for the same cache capacity; the host must accordingly increase its read rate. The chip also provides two general-purpose digital pins: GPIO0 and GPIO1. High sampling rates and long caching durations cannot be achieved simultaneously. When designing for the upper limit of 16 kHz, the cache capacity and read cycle must first be matched appropriately; the specific behavior of the FIFO after it becomes full must be confirmed according to the technical documentation or the actual device specifications.

Q12: What are the packaging options, temperature ranges, and ordering details?

A: The product uses the OLGA-24 package; the product specifications on the home page also mention the OLGA package integrated with a high-performance photodiode. The current ordering information sheet lists only the CBMPD188B/OLGA-24 model, with a temperature range of −40°C to 85°C and a storage temperature range of −45°C to 125°C. The ordering model corresponding to the package integrated with the photodiode shall be subject to the officially published ordering information.

On-site troubleshooting of detection issues

Q13: Under strong background light, the reading baseline is elevated, and there is a suspected false trigger in the smoke detection system. Where should I start my investigation?

A: The following explanation follows the general troubleshooting approach for optical detection; the specific smoke-alarm performance must be verified using the complete device. First, determine whether the environmental-light suppression is within its effective range. The 60 dB environmental-light suppression covers the frequency range from DC to 1 kHz, corresponding to the low-frequency background generated by natural and artificial lighting; the actual performance must be verified under the target optical path conditions and in the actual field environment. If the reading fluctuates slowly in response to changes in illumination, check whether the optical path shielding is properly implemented and whether the incident angle falls within the region of relatively higher sensitivity. Next, verify the range settings: under strong background light, consider using a smaller feedback resistor to maintain the saturation current. A value of 12.5 kΩ corresponds to a TIA saturation current of 100 µA; 1.6 MΩ corresponds to only 0.78 µA. Once the front-end stage saturates, the signal read by the subsequent algorithm may be distorted. Issues related to the background should first be addressed by examining the optical path and the range settings: simply raising the detection threshold may mask the fact that the front-end stage has already saturated.

Q14: The readings for weak smoke signals are unstable and the noise level is relatively high. How can the source of the issue be identified?

A: Investigate the issue from three perspectives. First, examine the feedback resistor value: the equivalent input noise (with the LED off and a 4 µs integration window) decreases from 4.5 nA rms at 12.5 kΩ to 0.06 nA rms at 1.6 MΩ; in applications involving weak signals, a higher-resistance resistor may be considered. Second, examine the integration and conversion configuration: confirm whether the multi-pulse integration mode is enabled and whether NUM_REPEAT_TSX is configured as required. Third, examine the power supply and decoupling: connect an external 1 µF capacitor from the VREF pin to AGND; AGND, DGND, and LGND correspond to the analog ground, digital ground, and LED driver ground, respectively. For weak-signal paths, first verify the operating mode and integration configuration, then consider whether the device itself may be the source of the problem.

Q15: How can I troubleshoot the issue if I cannot read data via I2C, or if the FIFO read values are discontinuous?

A: The issue should be analyzed across four layers. First, the electrical layer: the external pull-up resistors on SCL/SDA should be no less than 800 Ω, and the bus load should not exceed 30 pF. The digital voltage level should be based on IOVDD and matched to the level on the master-control side; long traces or the connection of multiple devices will increase the load. Second, the rate layer: the upper limit for FSCL is 1000 kbps; beyond this limit, communication stability will decline. Third, the configuration layer: the four time slots can be configured independently; verify that the read object matches the current time-slot and channel configuration. Fourth, the buffering layer: at high sampling rates, the 1024-byte FIFO may become full or data may be lost; the read cycle should be shortened; the specific behavior shall be confirmed in the technical documentation. First, use an instrument to measure the SCL/SDA waveforms to rule out issues at the electrical layer; then verify the configuration parameters. This approach will enable more efficient troubleshooting.

[Selection Summary]

The CBMPD188B integrates the photodetector measurement analog front end, ADC, LED driver, timing controller, and 1024-byte FIFO into a single chip. It supports the detection of weak optical signals, offering a dynamic range of 129 dB (in the receive link and for single sampling), 60 dB of high ambient light rejection, and ADC output resolution configurable up to 24 bits. When selecting the device, first determine the TIA feedback resistor based on the target photodetector current range; then verify whether the power consumption under the typical operating conditions of 20 µW is feasible, taking into account the number of time slots and the sampling rate; finally, confirm the I2C bus load and package type to complete the initial selection evaluation. The specific model to be ordered, which integrates the photodiode package, and the capability for multiple LEDs to operate simultaneously shall be subject to the information released officially.

Author: Xiao Fang Source: Corebai

Share:0

010-62106066

( Monday to Friday 9:00 - 18:00 )

704-705, Block D, Building 2, No. 9 Fenghao East Road, Haidian District, Beijing

sales@corebai.com

Wechat Public Account

© Copyright 芯佰微电子(北京)有限公司 京ICP备15051729号